>Main Specifications for SJ-210, 4mN type | |
>Model No. | |
>Standard drive unit | |
Retractable drive unit | |
Transverse tracing drive unit | |
>(Type of detector) | |
SJ-210
(0.75mN type) | |
SJ-210
(4mN type) | |
SJ-210
(4mN type) | |
SJ-210
(4mN type) | |
>inch/mm | |
178-561-01A | |
178-561-02A | |
178-563-02A | |
178-565-02A | |
Measuring | |
X axis | |
>69” (17.5mm) | |
22” (5.6mm) | |
Z axis Range | |
>14200 ?m (-7900?m ±6300?m (-200?m ±160?m) | |
(Detector) Range | |
>14170?in/8?ïn (360?m/0.02 ?m), 4000?in/2 ?in (100?m/100 ?m / 0.006 ?m), 1000?in/08?in 925?m/0.002?m | |
>Measuring Speed | |
>Measuring 0.01, 0.02, 0.03 in/s (0.25mm/s, 0.5mm/s, 0.75mm/s) Returning 1 mm/s | |
>Measure Force/Stylus Tip | |
>0.75 mN type: 0.75mN/2?uR 60°, 4mN type: 4mN / 5?mR 90° | |
>Skid Force | |
>Less than 400mN | |
>Applicable Standards | |
>JIS ‘82 / JIS ‘94 / JIS ‘01 / ISO ‘97 / ANSI / VDA | |
>Assessed Profiles | |
>Primary profile / Roughness profile / DF profile / Roughness profile-Motif | |
>Evaluation Parameters | |
>Ra, Rc, Ry, Rz, Ra, Rt Rmax, Rp, Rv, R3z, Rsk, Rku, RPc, Rsm, Rzimax, S, HSC, RzJIS, Rppi, R?a, R?q, Rir, Rmr, Rmr(c), Roc, Rk, Rpk, Rvk, Mr1, Mr2, A1, A2, Vo, Rpm, tp, Htp, R, Rx, AR, Possible Customize | |
>Analysis Graphs | |
>Bearing area curve / Amplitude distribution curve | |
>Filters | |
>Gaussian, 2CR75, PC75 | |
Cut Off Length | |
?c | |
>0.003, 0.01.0.03, 0.1” (0.08, 0.25, 0.8, 2.5mm) | |
?s | |
>100, 300?in (2.5, 8?m) | |
>Sampling Length | |
>0.003, 0.01, 0.03, 1” (0.08, 0.25, 0.8, 2.5mm) | |
>Number of Sampling Lengths (xn) | |
>arbitrary length 0.01 - 63” (.001” interval) (0.3 - 16.0mm: 0.01mm interval) | |
x1, x2, x3, x4, x5, arbitrary length (0.3 - 5.6mm: 0.01mm interval) | |
>LCD dimensions | |
>1.45 x 1.93” (36.7 x 48.9 mm) | |
>Display Languages | |
>Japanese, English, German, French, Italian, Spanish, Portuguese, Korean Traditional Chinese, Simplified Chinese, Czech, Polish, Hungarian, Turkish, Swedish, Dutch | |
>Calculation Result Display | |
>Vertical display: 1 parameter / 3 parameter / trace to measurements
Horizontal display: 1 parameter / 4 parameter / trace to measurements
(Horizontal display is invertable) | |
>Printing function*1 (Dedicated printer is required separately) | |
>Measurement conditions / Calculation results / Calculation results for each sampling length / Assessed profile / Bearing area curve / Amplitude distribution curve / Environment setting information | |
>External I/O | |
>USB I/F, Digimatic Output, Printer Output, RS-232C I/F, Foot SW 1/F | |
> Customization | |
>Desired parameters can be selected for calculation and display | |
> GO/NG judgment*2 | |
>By max value / 16% / Standard deviation | |
> Storage of measurement condition | |
>Save the conditions at power OFF | |
Functions | |
Storage | |
>Internal memory: Measurement condition (10 sets), Measured profile (1 set), Memory card (Option): 500 measurement conditions, 10000 measured profiles, 500 display images, Text file (Measurement conditions / Measured profile / Assessed profile /
Bearing area curve / Amplitude distribution curve) | |
Calibration | |
>Auto-calibration with the entry of numerical value / Average calibration with multiple measurement (Max 5 time) is available | |
>Power-Saving Function | |
>Auto-sleep off function (10-600sec) *3 | |
>Power Supply | |
>Two-way power supply: baqttery (rechargeable Ni-MH battery) and AC adapter
*Charging time: about 4 hours (may vary due to ambient temperature)
*Endurace: about 1000 measurements (differs slightly due to use conditions / environment) | |
Size
W x D x H | |
Display unit | |
>2.05 x 2.6” x 6.3” (52.1 c 65.8 x 160mm) | |
Drive unit | |
>4.5 x .9 x 1.02” (115 x 23 x 26mm) | |
>Mass | |
>About 1.1 lbs. (500 g) (Display unit + Drive unit + Standard detector) | |
>Standard Accessories | |
>12BAA303 Connecting cable *4
178-601 Roughness specimen
12BAK699 Carrying case
12BAK700 Calibration stage
12BAK820 Protective sheets for display
AC Adapter
Operation manual
Quick reference manual
Warranty | |
12BAA303 Connecting cable *4
178-605 Roughness specimen
12AA#643 Point-contact adapter
12AA#644 V-type adapter
12BAK700 Calibration stage
12BAK820 Protective sheets for display
AC Adapter, Operation manual
Quick reference manual Warranty | |
>*1 Order the 51-210 printer (No. 178-412A, optional accessory) separately
*2 Standard deviation only can be selected in ANSI. 16% rule cannot be selected in VDA
*3 Auto-sleep function is invalid when AC adaptor is used.
*4 For connecting the calculation display unit and drive unit | |