โพสเมื่อ
ชื่อสินค้า
เครื่องวัดอัตราการไหลของของเหลวแบบติดตั้งชนิดอัลตร้าโซนิค Integrated Flowmeter
การขนส่ง
จัดส่งทั่วประเทศ
รายละเอียด:
Integrated Flowmeter / LRF-2000F
- LRF-2000F integrated ultrasonic flow meter integrates main unit and transducers into one unit. The transducers are installed into pipeline by screw or flange.
Features
High Accuracy measuring
Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1%
Wide Measuring Range
Several types transducer for selection, measuring pipe size from DN 15mm to DN 6000mm
High Protection Grade
Protection grade of primary meter is IP68, can work in 2m of water
Easy to Operate
Browse data with magnetic stick on primary meter or reset parameter on secondary meter
Multi-display
Integrate signal detecting and flow measuring on primary meter, display accumulated/instantaneous flow, velocity in circle; secondary meter can also display over 100 menus
Far Transmission Distance
Connect primary and secondary meter through RS-485 interface, normal cable replaces special cable, transmission distance up to 1000m . Solve the problems of high cost of special cable, poor anti-interference, short transmission distance etc.
Optional Main unit
Functional Type LRF -2000F |
Add the following function except above ones:
- IP68, can work in 2m of water
- 3 channel 4-20mA analog input
- 2 channel tri-wire system resistance signal input of PT-100
- Isolation RS232/RS485 output, 2 channel isolation OCT output
- 1 channel isolation 4-20mA output (tow-wire system)
| |
|
" src="/UpLoadFile/daoshengerchibiaobig.jpg" /> | |
" src="/UpLoadFile/panzhuangshibig.jpg" /> | |
" src="/UpLoadFile/fangbaoshi.jpg" /> | |
Wall-mount(LRF-2000FW)
- For hanging installation
- Size: 178 x 165 x 55mm
|
Panel-mount (LRF-2000FS)
- For instrument panel installation
- Panel size: 152 x 76mm
|
Explosion-proof (LRF-2000FD)
- Explosive-proof Grade is DIIBT4
- Size: 298 x 298 x 110mm
|
Optional transducer
Feature | |
Functional Type | |
Clamp-on transducer | |
LRF-2000FNB |
- Instatolling without stopping flow and no pressure drop
- Measuring accuracy up to ±1%
- Easy install and maintain, user can install themselves
- The lowest price and independent of pipe size
- Suitable for good conditons
|
|
Insertion transducer | |
LRF-2000FNC |
- Installing without stopping flow and no pressure drop
- Measuring accuracy up to ±1%
- Installing with special tapper after training
- Higher price and independent of pipe size
- Better receiving signal, stability and reliability for long time working
|
|
Flange connection transducer | |
LRF-2000FNG |
- Installing with cutting pipe and stopping flow, no pressure drop
- Measuring accurary up to ±0.5%
- Installing and maintaining with stopping flow, user can install by themselves
- Price increased with measuring pipe size
- The highest accuracy, better receiving signal, stability and reliability for long time working
|
|
General Specification
>
Optional Transduers | |
Model | |
Measuring Range | |
Liquid Temperature | |
Accuracy | |
Clamp-on | |
TS-2(small size) | |
LRF-2000BNB1 |
DN15 -100mm |
-30C ° ? 90C ° | |
Better than
±1% | |
| |
TM-1(medium size) |
LRF-2000BNB2 |
DN50 -1000mm |
TL-1(large size) |
LRF-2000BNB3 |
DN300 -6000mm |
High-tem clamp-on | |
HTS-1(small size) |
LRF-2000BNB4 |
DN15 -100mm |
-30C ° ? 160C ° | |
|
HTM-1(medium size) |
LRF-2000BNB5 |
DN50 -1000mm |
Insertion | |
TC-1(standard) |
LRF-2000BNC1 |
DN80 -6000mm | |
-40C ° ? 160C ° | |
|
TLC-2(lengthen) |
LRF-2000BNC2 |
Prover Section | |
Prover Section | |
LRF-2000BNG | |
DN15 -1000mm
(see appendix 2) | |
-40C ° ? 160C ° | |
Better than
±0.5% | |
|
Power Supply |
>
Main unit: 8-36VDC , long distance display meter: AC220V or DC24V | |
Input |
>
3 channel 4-20mA analog input, 2 channel Tri-wire
resistance signal input (PT100) | |
Output |
>
Isolation RS232/RS485 output, 2 channel isolation OCT output,
1 channel isolation 4-20mA output (two-wire system) | |
Communication Protocols |
>
Compatible with METER-BUS protocol, MODBUS protocol, Fuji
extended protocol and general water meter protocol. | |
Structure of UFM
Single point measuring (Several optional secondary meter for long distance display and parameter setup) |
|
Network structure (For remote monitor and data collector) |
RS-485 bus (transmission distance up to 1000m ) 24V power supply |
|
Note:power supply and communicate with four-core cable (Red: 24V+, Black: 24V-, White: 485+, Green: 485-) |
คำค้นหา:
โฟมิเตอร์ วัด อัลตร้าโซนิค ultrasonic flowmeter