Operating temperature range
(during sterilizing) | |
105 - 123°C | |
105 - 132°C | |
Operating pressure range | |
0 - 127kPa | |
0 - 186kPa | |
Maximum operating pressure | |
147kPa | |
216kPa | |
Temperature control | |
Digital, microprocessor controlled | |
Temperature display / display range | |
Digital / -15 - 180°C | |
Pressure display / display range | |
Analog / 0 - 250kPa | |
Analog / 0 - 400kPa | |
Heat source | |
1.5kW electric heater | |
2.0kW electric heater | |
Timer control
| |
Digital, microprocessor controlled | |
Timer display | |
Digital | |
Timer
display range | |
Sterilizing mode: | |
1 - 240min. or continuous | |
Sterilizing-warming mode: | |
1 - 240min. (sterilizing) / 1 - 8hours (warming) | |
Heating mode: | |
1 - 8hours | |
Start-timer setting range | |
1 - 99hours in each operation mode | |
Memory function | |
A set of temperature and time setting in each operation mode | |
Safety devices | |
• Inside the chamber overheat prevention, • Outer wall of the chamber overheat prevention, • Overpressure prevention, • Temperature sensor disconnection prevention, • Empty heating prevention, • Leakage breaker, • Safety valve | |
Malfunction prevention devices | |
• Low water level detection, • Exhaust valve knob open/close detection,
• Insufficient sterilization detection, • Chamber lid open/close detection | |
Leakage
breaker | |
Rated breaking current: | |
20A (120V) , 15A (220 / 230 / 240V) | |
30A (120V) , 15A (220 / 230 / 240V) | |
Rated sensed current: | |
30mA (120V) , 10mA (220 / 230 / 240V) | |
Protection type | |
Class 1 equipment | |
Operating
environment | |
Ambient temperature: | |
5 - 35°C | |
Relative humidity: | |
30 - 85% | |
Atmospheric pressure: | |
700 - 1060hPa | |
Gradient: | |
Within 2° | |
Dimensions | |
?248 x 543mm | |
?325 x 740mm | |
Usable dimension | |
?236 x 450mm | |
?312 x 635mm | |
Capacity of chamber | |
22? | |
53? | |
Chamber material | |
SUS304 | |
Capacity / material of exhasut bottle | |
3? / polyethylene | |
Type / material of lid gasket | |
Accommodating internal pressure / silicone rubber | |
Dimensions of main unit (mm) | |
400W x 460D x 920H (Height from floor to control panel:705) | |
490W x 560D x 1090H (Height from floor to control panel:875) | |
Net weight | |
50kg | |
80kg | |
Rated Voltage | |
AC 120 / 220 / 230 / 240V | |
Power input | |
15A (120V), 7A (220 / 230 / 240V) | |
20A (120V), 10A (220V), 9A (230 / 240V) | |
Power supply requirements | |
Single-phase 120V AC (50 / 60Hz) 15A or above | |
Single-phase 120V AC (50 / 60Hz) 20A or above | |
Single-phase 220 / 230 / 240V AC (50 / 60Hz) 15A or above | |
Power Comsumption (calorific value) | |
1.5kW (1290kcal/h) | |
2kW (1720kcal/h) | |
Accessories | |
• Stainless steel basket with slatted bottom plate 1, • Water level sensor 1,
• Inspection sheet 1, • Warranty card 1, • Customer card 1, • Operator's manual 1,
• Clear plastic accessory case 1, • Attachment screw for clear plastic accessory case 1 | |
Stainless basket 1 (?224 x 376mm) | |
Stainless basket 2 (?300 x 182mm) | |