ORION COOLANT CHILLER, OIL CHILLER
โมเดล
RCC750B1, RCC1500B1
รายละเอียด:
ORION
COOLANT CHILLER, OIL CHILLER
And coolant chiller ...
Is a device for temperature control (liquid and grinding cutting fluid) water-soluble coolant to use when processing such as metal, plastic, ceramic machine tools such as grinders · NC lathe machining center (MC) · NC.
Simply connect the pipe to the tank!
Can be retrofitted easily to various machine tools such as grinders · NC lathe machining center (MC) · NC.
Feature
- Effective
Coolant fluid temperature is controlled to ± 0.5 ? of the temperature setting. Helping to increase the accuracy of your production.
- Economy
Energy saving from our DC motor and Inverter control. Coolant evaporation losses cut in half!!
- Ecology (Environment)
Reduced bacteria production means less decomposition and fewer foul odors thus improving your working environment.
Conversion from "Immersion" to "Circulation"
Specification
Specifications Table
| | RCC750B1 | | RCC1500B1 | | RCC750B1-H | | RCC1500B1-H | |
Performance | |
Cooling capacity ? 1 | |
2.5kW | |
4.65kW | |
2.5kW | |
4.65kW | |
The operating ambient temperature range | |
10 ~ 40 ? | |
Use liquid temperature range | |
(Differential temperature control and constant temperature control) 15 ~ 40 ? | |
Hydraulic fluid temperature range electric heater for heating | |
- | |
Below 25 ? | |
Liquid temperature control accuracy ? 1 ? 2 | |
Set temperature ± 0.5 ? | |
Below the set temperature 0.5 ? ± | |
Power | |
3-phase 200V (50Hz/60Hz), 220V (60Hz) | |
3-phase 200V (50Hz/60Hz) | |
Power consumption ? 1 | |
1.3kW | |
2.1kW | |
1.5kW ? 3 | |
2.4 kW ? 3 | |
Temperature controller | |
Digital electronic temperature control | |
Electric heater for heating | |
- | |
1.2kW | |
2.1kW | |
Product weight | |
70kg | |
85kg | |
74kg | |
89kg | |
? 32 ? 20 ? 1 liquid temperature, room temperature, 200V, 60Hz
when the cooling load and ambient temperature stability ? 2, except in the following cases, however.
??4 minutes ? compressor starts up. If the compressor is ON-OFF low cooling load ?. If the set temperature 40 ? 31 ? ~ ?.
? When energized heater 3 heating
? Temperature control is also possible to control the temperature difference (temperature sensor body is optional).
? We are also prepared with a specification of the heater heating.
? The coolant available, please contact us.
คำค้นหา: