โพสเมื่อ
ชื่อสินค้า
Bomb Calorimeter
รายละเอียด:
Technical Specifications
Operating Temperature
0-60 Degrees C
__________________________________________
Temperature Resolution
0.000001 Degrees C
_________________________________________________
Repeatability
0.1% RSD
_________________________________________________
Resolution
0.001 (MJ/Kg)
_________________________________________________
Results per hour
10 sampes per hour using two vessels
__________________________________________
Power
90 - 260 VAC
Features
- Easy to maintain, self system test for technicians
- Compact size - able to fit more systems into a standard laboratory
- Fully automatic operation - temperature readings and calculations are done for you
- Possible to network up to 7 calorimeters
- Rapid and accurate determinations
- 10 samples per hour using the CAL2k-2 Cooler and 2 vessels
- Isothermal design using a waterless patented vessel (no bucket, spillage or measuring)
- Large memory for storing more than 2000 determinations, including operating conditions and user statistics
- Automatic correction for firing wire, cotton, spikes etc
- Fully automatic calibration, with 10 stored calibrations per vessel for standard deviation
- Calibrated sensors built into vessel wall
- Can use spiking for hard to combust samples
- Intelligent "SMART" vessel with fault diagnostics and calorific processor
- Vessels are pre-programmed for 5000 determination cycles before inspection
- Adjustable firing limits set per vessel
- High and low mass limits
- Determination cycle adjustment
- Other features include user, group and sample ID
- CE Certified
- Precise and reproducible determination of gross calorific values according to ISO 1928, DIN 51900 and BS1016:105
Software Features
- User controlled access for vital and routine operations
- Automatic results retrieval for selected and formatted data
- Weigh station operation
- Calorimeter and vessel setup
- Calibration management
- Service and maintenance routines
- Filing, printing and other operator functions, including data export to common formats
- Real time graphical temperature display
- Network status display
- Grouped sample determinations and analysis
Complete CAL2k System
Complete system consists of the following:
CAL2k-1 Calorimeter
CAL2k-1-KT Calorimeter Installation Kit
CAL2k-2 Cooler
CAL2k-2-KT Cooler Installation Kit
CAL2k-3 Filling Station
CAL2k-3-KT Filling Station Installation Kit
CAL2k-4 Vessel
CAL2k-4-KT Vessel Installation Kit
Optional Extras (Recommended or Required):
CAL2K-PCS CAL2K Windows Operating Software on CD
CAL2K-PCC PC Cable (required for software)
CAL2k-5 Docking Station
CAL2k-CIC CAL2K Interconnection Cable (Required only when Networking of units)
REGULATOR High Pressure Oxygen Regulator (Required and MUST be supplied before installation)
It is important to note that a High Pressure Oxygen Regulator capable of filling the vessel to 3Mpa (3000Kpa, 30 bar, 30 atm) is required and must be available/supplied prior to installation of the unit.
Items to Source Locally
Balance (Recommended Satorius Balance CP64 or equivalent)
Water Tap Connection
PC with Windows 98/2000/XP/NT4.0 Installed (Required only if running software - a PC is not required to operate the unit)
คำค้นหา: