Air relative humidity range: |
0 to 100% |
Accuracy of relative humidity measurement: |
±2.5% relative humidity from 5 to 95% at 23°C |
Accuracy of temperature output: |
±0.4°C from -30 to +100°C
±0.4% from reading over +100°C |
Available temperature units: |
degrees Celsius, Fahrenheit |
Accuracy and range of dew point temperature output:
- for more details see graphs |
±1,5°C at ambient temperature T<25°C and RH>30%
range -60 to +80 °C |
Accuracy and range of absolute humidity output: |
±3g/m3 at ambient temperature T < 40°C
range 0 to 400 g/m3 |
Accuracy and range of specific humidity output: |
±2g/kg at ambient temperature T < 35°C
range 0 to 550 g/kg |
Accuracy and range of mixing ratio output: |
±2g/kg at ambient temperature T < 35°C
range 0 to 995 g/kg |
Accuracy and range of specific enthalpy output: |
±3kJ/kg at ambient temperature T < 25°C
range: 0 to 995 kJ/kg |
Temperature operating range of case with electronics: |
-30 to +80°C |
Temperature operating range of LCD display: |
readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C |
Range of humidity sensor temperature compensation: |
-30 to +125°C |
Current outputs - two-wire connection: |
4-20mA, galvanic isolated with dual-output models |
Configuration of outputs and output range: |
user adjustable from the PC |
Filtering ability of sensor cover: |
0.025mm - filter with stainless steel mesh |
Protection of the case with electronics: |
IP65 electronics, IP40 sensors |
Power: |
9-30Vdc |
Warranty: |
two years |