Instrument | |
Measuring Capability | |
ST1XX Models: Flow rate, total flow and temperature
STP1XX Models: Flow rate, total flow, temperature and pressure | |
Basic Style | |
ST100:Insertion, single-point
ST100L:In-line (spool piece), single-point
ST102:Insertion, dual-element system
ST110:Insertion, single-point with VeriCal? capability
ST112:Insertion, dual-element system with VeriCal? capability
STP100:Insertion, single-point with pressure measurement
STP102:Insertion, dual-element system with pressure measurement
STP110:Insertion, single-point with pressure measurement and VeriCal? capability
STP112:Insertion, dual-element system with pressure measurement and VeriCal? capability
| |
Flow Measurement Range | |
Insertion Style:0.25 SFPS to 1000 SFPS [0,07 NMPS to 305 NMPS]
ST100L In-line:0.0062 SCFM to 1850 SCFM [0.01 Nm3/h to 3,140 Nm3/h]
– Air at standard conditions; 70 °F and 14.7 psia [0 °C and 1,01325 bar (a)] | |
Temperature Measurement Range | |
Up to 850 °F [454 °C] commensurate with element; see Operating
Temperature in Flow Element specification | |
Pressure Measurement Range (STP Models) | |
Available Ranges:
0 psig to 50 psig [0 bar (g) to 3,4 bar (g)]
0 psig to 160 psig [0 bar (g) to 11 bar (g)]
0 psig to 500 psig [0 bar (g) to 34 bar (g)
0 psig to 1000 psig 0 bar (g) to 70 bar (g)] | |
Media All gases that are compatible with the flow element material | |
Accuracy | |
Flow:
Gas Specific Calibration: ± 0.75% reading, ± 0.5% full scale
SpectraCal Gas Equivalency: Typically ± 4% reading, ± 0.5% full scale; gas conditions specific to application will determine accuracy; utilize FCI's online tool, AVAL, to evaluate your application and provide expected accuracy
Temperature: ± 2 °F [± 1.1 °C] (display only, flow rate must be greaterthan 5 AFPS [1,5 m/sec])
Pressure (STP Models): ± 1.0% of span | |
Temperature Coefficient | |
With optional temperature compensation; valid from 10% to 100% of full scale calibration
Flow:Maximum ± 0.015% of reading / °F up to 850 °F[± 0.03% of reading / °C up to 454 °C]
| |
Repeatability | |
Flow: ± 0.5% reading
Temperature: ± 1 °F [± 1 °C] (flow rate must be greater than 5 AFPS[1,5 NMPS])
Pressure (STP Models): ? 0.1% of span | |
Turndown Ratio | |
Normally factory set and field adjustable from 2:1 to 100:1 within calibrated flow range; up to 1000:1 possible with factory evaluation of application | |
Temperature Compensation | |
Standard: ± 30 °F [± 16 °C]
Optional: ± 100 °F [± 55 °C]
| |
Agency Approvals (Pending) | |
FM, FMc:
ATEX and IECEx:
CPA, NEPSI, Inmetro,
GOST-R, GOST-K
Ex-rated pressure transducer STP Models:
FM, CSA:
ATEX:
Class I, Division 1, Hazardous Locations;
Groups B,C,D,E,F,G
Zone 1, II 2 GD Ex d IIC T4 (pending)
(pending)
Class 1, Division 1, Groups A,B,C,D
Dust ignition proof for Class 1, Division 1, Groups E,F,G
2 G Ex d C T4, Ex d IIC T5, Ex d IIC T6 | |
Calibration Performed on NIST traceable flow stands and equipment | |
Flow Element | |
Material of Construction All-welded 316L stainless steel. | |
Operating Pressure | |
Insertion Types
ST Models
Metal ferrule: 1000 psig [69 bar (g)]
Teflon ferrule: 150 psig [10 bar (g)] (200 °F [93 °C] maximum)
Fixed Connection NPT: 1000 psig [69 bar (g)]
Fixed Connection Flanged: per flange rating
STP Models: per above or pressure sensor rating, whichever is less
Inline Type (Model ST100L): 1000 psig [69 bar (g)]
| |
Operating Temperature (Process) | |
ST100, ST102 Insertion Style
All Flow Elements (– FPC, – FP and – S):
-40 °F to 350 °F [-40 °C to 177 °C]
-40 °F to 500 °F [-40 °C to 260 °C]
-40 °F to 850 °F [-40 °C to 454 °C] ST110, ST112 Insertion Style
– FP Style Flow Element:
-40 °F to 350 °F [-40 °C to 177 °C]
-40 °F to 500 °F [-40 °C to 260 °C] STP Series Insertion Style
– FP Style Flow Element:
Standard Pressure Sensor: -32 °F to 176 °F [0 °C to 80 °C]
Ex-rated Pressure Sensor: -22 °F to 212 °F [-30 °C to 100 °C] ST100L In-line Style
– FP and – S Style Flow Element:
-40 °F to 250 °F [-40 °C to 121 °C] | |
Process Connection | |
Compression FittingsModels ST100 and ST102 only
3/4" or 1" male NPT, stainless steel with adjustable Teflon ferrule or metal ferrule; or flanged tapped and threaded for 3/4" fitting, ANSI or DIN flanges
Compression fittings not available with 850 °F [454 °C] temperature versions of ST100 or ST102
Retractable Packing Glands
Low pressure 50 psig [3,5 bar (g)] or medium pressure 500 psig [34 bar (g)] with graphite or Teflon packing material; 1 1/4" male NPT or ANSI or DIN flange
Teflon packing required when process media is ozone, chlorine or bromine.
Remote configuration required with medium pressure packing gland.
Fixed Fittings / All Welded
1" male NPT or ANSI or DIN flange
Insertion Length
Field adjustable lengths:
1" to 6" [25 mm to 152 mm]
1" to 12" [25 mm to 305 mm]
1" to 21" [25 mm to 533 mm]
1" to 36" [25 mm to 914 mm]
1" to 60" [25 mm to 1524 mm] Fixed lengths from 2.6" to 60" [66 mm to 1524 mm]
| |
ST100L In-line Flow Tube | |
Flow element is threaded and keyed in an in-line flow tube, calibrated andsupplied as a spool-piece; options include low flow injection tubes and built-inVortab flow conditioners for optimum low flow rangeability and performance
Size: 1" diameter tubing; 1", 1 1/2" or 2" schedule 40 pipe
Length: 9 nominal diameters
Process Connections: Female NPT, male NPT, ANSI or DIN flanges, or butt weld prepared
Option: Flanges sized for flow tube
| |
Remote Transmitter Configurations: | |
Transmitter may be mounted remotely from flow element using interconnecting cable (up to 1000' [300 m])
| |
STP Models: Additional Specifications on Pressure Sensor
| |
Standard Sensor | |
PSI | |
Bar | |
PSI | |
Bar | |
PSI | |
Bar | |
PSI | |
Bar | |
Pressure range
Over pressure safety
Burst pressure
| |
50
100
250 | |
3,4
7
17,24 | |
160
290
500 | |
11
20
34 | |
500
1000
2500 | |
34
70
172 | |
1000
1740
7975 | |
70
120
550 | |
Wetted Materials:
Connection
Pressure sensor
| |
316L
PH 13-8 SS | |
316L
316L | |
316L
316L | |
316L
316L | | | | | |
Ex Rated Sensor | |
PSI | |
Bar | |
PSI | |
Bar | |
PSI | |
Bar | |
PSI | |
Bar | |
Pressure range
Over pressure safety
Burst pressure
| |
50
240
290 | |
3,4
16,55
20 | |
160
1160
1390 | |
11
80
95,84 | |
500
1160
5800 | |
34
80
400 | |
1000
1740
7970 | |
70
120
549,5 | |
Wetted Materials:
Connection
Pressure sensor
| |
Stainless steel
Stainless steel | |
Stainless steel
Stainless steel | |
Stainless steel
SS and Elgiloy | |
Stainless steel
SS and Elgiloy | | | | | |
Flow Transmitter/Electronics | |
Operating Temperature | |
0 °F to 150 °F [-18 ° to 65 °C] (all except dual element models)
Dual-element Models: 0 °F to 130 °F [-18 ° to 54 °C]
| |
Input Power | |
AC: 85 Vac to 265 Vac, 50 Hz to 60 Hz
DC: 24 Vdc ± 20%
| |
Outputs | |
Analog
Standard: Three (3) 4-20 mA*, 0-1kHz, or 0-10 kHz pulse/frequency4-20 mA outputs are user assignable to flow rate, temperatureand/or if so equipped, pressure; outputs are user programmable tofull flow range or subsets of full flow range; pulse/frequency outputis user selectable as pulse for external counter/flow totalizer, or as0-1 kHz or 0-10 kHz frequency representing flow rate
* Outputs are isolated and have fault indication per NAMUR NE43guidelines, user selectable
for high (>21.0 mA) or low (<3.6 mA)
Optional: Standard output plus two (2) 2A SPDT relaysRelays independently user assignable to flow, temperature orpressure; user programmable for hi/lo trip, hysteresis from 00.0 to99.9 counts and time delay from 00.0 to 99.9 seconds
Digital
Standard:
Optional:
USB, Ethernet
HART (comes standard with analog outputs, V7 compliant)
Foundation fieldbus H1, PROFIBUS PA or Modbus RS-485
(* ST100 Series is cerified by and registred with the Fondation Fieldbus Organization) | |
Auxiliary Inputs | |
Two 4-20 mA input channels; used for FCI administered specialconfigurations to allow ST100 Series to accept inputs from externaldevices such as gas analyzers, gas composition or pressure sensors | |
Enclosures | |
Main Transmitter / Electronics:
NEMA 4X, IP67; polyester powder coated aluminum; 4 conduit portsthreaded as 1/2 " NPT or M20x1.5; 7.74 " x 5.40 " x 5.00 " [196.6 mm x137.2 mm x 127 mm]; stainless steel enclosure pending
Local Enclosure (Remote Configuration):
Model ST100L, Models ST100 and ST102 without packing gland option:
NEMA 4X, IP67; polyester powder coated aluminum; 2 conduit portsthreaded as 1/2 " NPT or M20x1.5; 3.75 " x 4.00 " x 3.24 " [95 mm x 102 mmx 82 mm] Models ST100 and ST102 with medium pressure packing glandoption; ST110, ST112 and all STP Models:
NEMA 4X, IP67; polyester powder coated aluminum; 1 conduit portthreaded as 1 " NPT or M20x1.5;
5.40 " x 4.82 " [137.2 mm x 122 mm] | |
Data Logger | |
User programmable for readings per time increment to a maximumof 1 reading/second; removable, circuit board-mountable2GB micro-SD (secure digital) memory card supplied; storesapproximately 21M readings
in ASCII comma-separated format | |
Readout/Display and Optical Touch Buttons (Optional) | |
- Large 2" x 2" [50 mm x 50 mm] LCD; digital plus bar graph and engineering units
- Digital displays of flow rate, total flow, temperature and pressure (with STP models);
user selectable for engineering units
- Analog bar graph of flow rate
- Relay/alarm status indication
- User programmable 20 alphanumeric character field associated with each calibration group
- Set-Up & Service mode displays text and service codes
- Backlighted – backlight activated by proximity motion detection,or user may set for always on
- Four (4) optical touch buttons for user programming of instrumentset-up and service interrogation
- Optical touch button activation through front window – no needto open enclosure to access or activate
- Display is electronically rotatable in 90° increments to optimizeviewing angle
Note: If readout/display not ordered, all user set-up and service interrogationmust be done via computer
link to bus comm and/or USB port. | |
Other Options and Accessories | |
Vortab Flow Conditioners | |
Available for all line size applications; standard choice withModel ST100L (in-line) | |
Sun Shield, FCI part number 022378-01 | |
Shades main transmitter electronics and display from direct sunlight. 316LSS | |
VeriCal Kit, FCI part number 020849-03 | |
For use with VeriCal ready flow elements
(models ST110, ST112, STP110, STP112)
Portable test kit for controlling flow to elements, pressure regulation, digital pressure gauge and interconnection hose. | |
Ball Valves / Cable Glands | |
Element Coatings and Materials | |
For service in highly corrosive gases or with erosive particulates,FCI can provide special coatings and wetted materials to protectthe element and provide longer service life; examples include Kynar,Tantalum, and chromium carbide | |
Certification and Testing Documentation | |
NACE, CMTR's, CRN registration, oxygen cleaning, welding qualifications, NIST certs, pressure testing, dye penetrant, and more available.
Specifications at reference operating conditions of 70 °F, 14.7 psia [21.1 °C, 1.013bar (a)]and straight pipe run 20d upstream, 10d downstreamFCI is a continuous improvement company; specifications subject to change without notice | |