Technical Parameter | |
AN9651B(F) (6 in 1) | |
AN9641B(F) | |
AN9640B(F) | |
Ground
Bond
Test | |
No-load Output Voltage | |
| |
Current Presetting Range | |
AC 3A~30A 50Hz/60Hz 1A/step | |
AC 10A 25A 50Hz/60Hz | |
Current Accuracy | |
±(1.5% of setting+0.40A) | |
Current Stability | |
| |
Resistance Range/Accuracy | |
10~600m? ±(1.5% of reading+1.5% of range) | |
Resistance Up-Limit Range | |
3A?Current?10A:10~600m?; 11A?Current?25A:10~300m?;
26A?Current?30A:10~200m? 1m?/step | |
10A:10~600m?;
25A:10~300m?;
1m?/step | |
Resistance Low-Limit Range | |
0m? | |
Compensation Resistance Range | |
0~200m?,Automatic Measurement, ON/OFF | |
Voltage Range/Accuracy | |
30~7500mV ±(1.5% of reading+1.5% of range) | |
Voltage Up-Limit Range | |
30~7500mV 1mV/step | |
Voltage Low-Limit Range | |
0mV | |
Compensation Voltage Range | |
0~1000mV,Automatic Measurement, ON/OFF | |
Test Time Range/Resolution | |
1~999s 1s/step | |
Insulation Resistance Test | |
Rated Output Load/Current | |
2VA(1000V/2mA) 2mA | |
Output Voltage Range/Resolution | |
DC 500V/1000V | |
Output Voltage Ripple | |
| |
Output Voltage Accuracy/Resolution | |
±(3% of setting+3V) 5V | |
Resistance Range/Accuracy | |
?200M?: ±(3% of reading+3 counts);
>200M?: ±(8% of reading+8 counts) | |
Resistance Up-Limit Range | |
0~2000M? | |
2000M? | |
Resistance Low-Limit Range | |
0.3~2000M? 0.1M?/step(?100M?),1M?/step(>100M?) | |
Test Time Range/Accuracy | |
1~999s 1s/step | |
AC Hipot Test | |
Rated Output Load | |
500VA(AC:5000V/100mA) | |
100VA(AC:5000V/20mA) | |
Output Voltage Range/Freq/Resolution | |
500~5000V 50Hz/60Hz | |
Output Voltage Setting Range/Accuracy | |
Static:AC,500~5000V;Dynamic:AC,500~2500V; ±(3% of setting+10V) | |
Static:AC,500~5000V;
±(3% of setting+10V) | |
Breakdown Current Meas. Accuracy | |
±(3% of reading+0.03mA) | |
Breakdown Current Alarm Preset Range | |
Up-Limit:0.10-100.00mA;Low-Lmit:0-10.00mA; 0.01mA/step | |
Up-Limit:0.10-20.00mA;Low-Limit:0.0-10.00mA; 0.01mA/step | |
Compensation Current Range | |
0.00-10.00mA,Automatic Measurement, ON/OFF | |
Test Time Range | |
1~999s 1s/step | |
Rise Time Range | |
0~100s 1s/step | |
Leakage Current Test | |
Output Voltage Range | |
1.06 times of input voltage(output by isolated transformer) | |
external switching power or input by isolation mounting | |
Leakage Mode Setting | |
Static, Dynamic | |
Output Voltage Meas. Range/Accuracy | |
AC 60~280V/45~65Hz; ±(0.5% of reading+2 counts) | |
Leakage Current Setting Range | |
Up-Limit:0~9.999mA 0.001mA;Low-Limit:0mA | |
Compensation Current Setting Range | |
0~1000uA,Automatic Measurement, ON/OFF | |
Leakage Current Meas. Range/Accuracy | |
0.050mA~9.999mA/
DC~10kHz: ±(3% of reading+10uA);
10k~1MHz: ±(5% of reading+50uA) | |
Test Time Range | |
1~999s 1s/step | |
Power Test | |
Output Voltage Range | |
1.00 times of input voltage(output by isolated transformer) | |
External switching power or input by isolation mounting | |
Power Setting Range/Resolution | |
Up-Limit:6~6000W Low-Limit:0~6000W 1W/step | |
| |
Up-Limit:6~6000W Low-Limit:0~6000W 1W/step | |
Output Voltage Meas. Range/Accuracy | |
AC 60~280V; 45~65Hz: ±(0.5% of reading+2 counts) | |
| |
AC 60~280V; 45~65Hz: ±(0.5% of reading+2 counts) | |
Current Meas. Range/Accuracy | |
AC 0.030~3.999A,4.00~25.00A;
45~65Hz: ±(0.5% of reading+0.020A) | |
| |
AC 0.030~3.999A,4.00~25.00A;
45~65Hz: ±(0.5% of reading+0.020A) | |
Real-Power Meas. Range/Accuracy | |
10.0~199.9W: ±(0.5% of reading+5W)
200~6000W: ±(0.5% of reading+30W) | |
| |
10.0~199.9W: ±(0.5% of reading+5W)
200~6000W: ±(0.5% of reading+30W) | |
Power Factor Meas. Range/Accuracy | |
0.100~1.000; ±(2% of reading+2 counts) | |
| |
0.100~1.000; ±(2% of reading+2 counts) | |
Test Time Range | |
1~999s,1s/step | |
| |
1~999s,1s/step | |
Low Voltage Start Test | |
Output Voltage Range | |
1.00 times of input voltage(output by isolated transformer) | |
| |
Current Meas. Range/Resolution | |
Up-Limit:0.30~25.00A Low-Limit:0.00~25.00A 0.1A | |
| |
Output Voltage Meas. Range/Accuracy | |
AC 60~280V; 45~65Hz: ±(0.5% of reading+2 counts) | |
| |
Current Meas. Range/Accuracy | |
AC 0.030~3.999A,4.00~25.00A
45~65Hz: ±(0.5% of reading+0.010A) | |
| |
Test Time Range | |
1~999s 1s/step | |
| |
Display Mode | |
240×128 LCD Large Screen | |
Isolated Transformer Capacity | |
Single Phase:2000W~6000W | |
| |
Over-current Protection Limit | |
When current 30A,exceed 5s protection | |
Alarm Mode | |
Alarm with Sound and Light | |
Standard Interfaces | |
RS232 Interface, Alarm Light Interface, Remote Control Interface,AN97 Frequency Converter Power Supply Interface | |
| |
Interfaces Optional | |
RS485 Interface, Printer Interface, Foot Pedal Interface, On-off Interface | |
RS485 Interface, Foot Pedal Interface, On-Off Interface | |
Buzzer Alarm Sound | |
สามารถ เปิด และ ปิด ได้ | |
Test Group | |
15 กลุ่ม แต่ละกลุ่มมี 7 ขั้นตอน | |