Operating Principle

Highly reliable · Easy to clean · No moving parts · Accurate· Very useful in a laboratory or as a maintenance diagnostics tool


Measuring range :                   1 ppb - 2 ppm or 50 ppb - 25 ppm in liquids;0 - 4.2% or 0 - 50% in gases.

Accuracy :                             +/- 1 ppb or 0.002% varies with range selected

Temp. compensation :             PT 100

Operating Temp. :                  -5°C - +55°C (+23°F - +131°F)

Temp. resistance :                  up to max 130°C (266°F)

Pressure range :                     max. 12 bar g.

Materials in product contact :   1.4404 (316L) s/steel, Silicone, PTFE.US FDA Conforming

Local Display :                       ppb, ppm in liquids, %oxygen in gases Data logger function Manual and Automatic with selectable interval of 5-600s

Power Supply :                      Internal Rechargeable Battery


Description

      The new portable CentecOxytrans MO2-meter continuously measures the exact content of oxygen in liquids and gases. The sensor is especially designed for breweries and other high end process requirement applications, e.g. power plants or bioreactors. The optical principle of measurement is based on the effect of dynamic luminescence quenching by molecular oxygen. The indicator layer on the glass installed in the measuring head is illuminated with a blue-green-light. This excites the indicator molecules causing  them to emit a red light. The level of red light is detected by an internal receiver. If oxygen is present, the energy transfers to the oxygen molecule. After the collision with the indicator layer the oxygen molecule is transferred from its ground state (triplet state) to its excited singlet state. As a result, the indicator molecule does not emit the luminescence. The luminescence signal decreases linear to the oxygen content. This decrease is the basis for the oxygen calculation. The O2-concentration can be displayed locally on the instrument screen and can also data log approx 5000 values.