Ranges: (Series UTS Sensor Dependent) 2 to 82 ft (0.6 to 25 m).
Accuracy: 0.25% of max range.
Resolution: 0.04" (1 mm).
Temperature Limits:
UTC-XXX-1XX-X: -40 to 140°F (-40 to 60°C);
UTC-XXX-2XX-X: -4 to 140°F (-20 to 60°C).
Temperature Compensation: Automatic.
Power Requirement:
UTC-XXX-1XX-X: 18 to 30 VDC 6 W;
UTC-XXX-2XX-X: 100 to 240 VAC 50/60 Hz.
Switch Type: 5 SPDT relays.
Electrical Rating: 1 A @ 300 VAC, 1 A @ 150 VDC.
Output Signal: 4 to 20 mA.
Max. Loop Resistance: 750 ? @ 24 VDC.
Electrical Connections: Screw terminal.
Conduit Connection: 1/2" female NPT, M20 x 2.5 (optional).
Enclosure Material: ECTFE.
Enclosure Rating: NEMA 4X (IP65).
Mounting Orientation: Vertical.
Memory: Non-volatile.
Display: LCD (6 digit).
Units: m, in, ft, m3/hr, GPM interchangable.
Programming: 4 button.
Weight: (3.5 lb) 1.6 kg.