BANGKOK INSTRUMENT CO.,LTD
บริษัท บางกอก อินสตรูเมนท์ จำกัด
02-175-2646-7 , 086-612-2065
โพสเมื่อ
Multi Transmitter,เครื่องส่งสัญญาณ,เครื่องแปลงสัญญาณมาตรฐาน,humitron,Automation and Electronics/Electronic Components/Transmitters
รหัสสินค้า
NANA-149610
ชื่อสินค้า
Multi Transmitter
แบรนด์
humitron
โมเดล
HMX350
รายละเอียด:


 

Measurement of Multiple Parameters
HUMITRON® HMX350 series can measure many other parameters as well as temperature and relative humidity as follows:


- RH: Relative Humidity
- T: Temperature
- Td: Dew-Point Temperature
- Tf: Frost-Point Temperature
- Tw: Web-Bulb Temperature
- Pw: Water Vapour Pressure
- Pws: Saturated Water Vapour Pressure
- A: Absolute Humidity
- x: Mixing Ratio
- h: Enthalpy
- Aw: Water Activity
- Aw: Water Activity in Oil
- ppm: Mass of Water in Oil


Multiple Analog Signal Outputs(4-20mA)
With 3 analog signal outputs(4-20mA), users can organize the parameters as desired. Output range is also configurable.


Multiple Relay Outputs
With 3 relay points, users can select the parameters and organize as desired. Output range is also configurable.


Easy Network Setup(RS485 and Ethernet)
RS485 and Ethernet(external conversion module) enables easy network setup to monitor remote date and data log.


Powerful Data Log
Parameters(temperature, humdity, dew point, and etc.) are being stored in the nonvolatile memory regularly and it is easy to analyze it using HMX data logging and analaysis software.



Various Installations and Filter Protection
- HMX350W: Wall mounting Type
- HMX350R: Remote Sensing probe(sensor separated from main body)
- HMX350P: Remote Sensing probe for high pressure (Maximum 30 bars)
There are 3 options in probe(110, 220, and 330mm) and 2 options in filter(standard sintered alloy filter and mesh filter for high humidity).

VFD Module
For industrial uses, VFD module is deployed and has many advantages in terms of stability and visibility.



? Technical Specifications

?HMX350WHMX350RHMX350P
>Dimensions >184(W) X 100(H) X 65(D)mm
>Power >15 - 32Vdc or 12 - 24Vac
>Power Consumption >200mA(24Vdc)
>Cable Fitting >Three M12(Aluminum)
>Connection >Screw Terminal up to 1.5?(AWG 16)
Temperature
Sensor
Range >-50~200?
(220? - Short Term)
Element >PT100(Tolerance Class A)
Accuracy >±0.2°C(Full Range)
Humidity
Sensor
Range >0~100%RH
Accuracy
(Incluidng Hysteresis,
Non-Linearity, and Repeatability)
>Standard: ±2.0%RH(0~90%RH), ±3.0%RH(90~100%RH)
Special Calibration: ±1.0%RH(0~90%RH), ±2.0%RH(90~100%RH)
Response Time with
Metal Grid Filter at 20°C/t90
>< 15 sec.
>Analog Signal Output >4-20mA(3 Points), Load Resistance ? 500?
User-Configurable
>Relay Output >Contact(3 Points)
User-Configurable
>Pressure Range for Pressure Tight Probe >0.01~20bar(0.15~300psi)
>System Requirements for Software >Windows 2000 or Later, Serial Interface
>Housing/Protection Class >Al/IP65(NEMA 4)
>Mount >Wall
>Remote Probe - OK OK(High Pressure)
>Operation >Temperature -40~60?(Electronic Parts)
>Storage >Temperature -40~60?(Electronic Parts)

 



? Diagram 
? Dimensions

คำค้นหา:
เครื่องแปลงสัญญาณมาตรฐาน เครื่องส่งสัญญาณ

บริษัท บางกอก อินสตรูเมนท์ จำกัด

BANGKOK INSTRUMENT CO.,LTD

288/123 ม.14 ซ.กิ่งแก้ว 37/4 ถ.กิ่งแก้ว ต.ราชาเทวะ อ.บางพลี จ.สมุทรปราการ 10540

02-175-2646-7 , 086-612-2065
02-175-2648

Contact: นพดล อสุนี ณ อยุธยา